Loading...

Lae at2 5 controller manual

Lae at2 5 controller manual
programmed controller at2 blue grd evap fan capacitor sc lae electronic at2-5 control 115v, speed control & solenoid factory & field wiring brown blue black black 3. for motor amps see rating sticker on outside of unit. sc = speed control factory wiring legend grd = ground 1. use copper conductors only 2. unit must grounded field wiring lls = liquid line solenoid 2 5 10 11 ambient air white
The controller is provided with a screw terminal block to connect cables with a cross section up to 2,5 mm 2. Before connecting cables make sure the power supply complies with the control’s requirements. Separate the probe cables from the power supply cables, and the outputs and the power connections. Do not exceed the maximum current
See image 5. HOW TO LOCK AND UNLOCK LAE CONTROLLER: Image 3: If “no” appears on screen, the controller is unlocked. 3 2 1 5 4 Image 4: If “yes” appears on screen, the controller is locked. LAE Control Info / Set Point Button Manual Activation Up Button Manual Defrost / Down Button Stand-By Button LAE Control Icons Compressor Running
LAE Control Equipment / LAE AT2-5 Three Relay Temperature & Defrost Controllers / AT2-5BQ4E-1JW; AT2-5BQ4E-1JW SKU: AT2-5BQ4E-1JW. Availability: In stock. 0.00 . Qty: • A universal refrigeration controller • Replaces the function of a thermostat, a defrost clock, a defrost klixon, a fan delay switch, and temperature gauge. • A moderate capacity relay for compressor control (5 amp
True Manufacturing Company TGU-2 Installation Manual Page 18 LAE Electronic Control Info/Set Point Manual Defrost/ Button Down Button HOW TO ADD A “DEFROST CYCLE” May need to unlock control. WHY: THE DEFROST TIME IS THE TIME OF DAY DEFROST CYCLES ARE INITIATED. Time of Day must be set ensure that factory set defrost times are occur at the correct times. Page 19: Operation True Food
15/02/2018 · Tutorial on how to set the alarm values on an LAE controller
LAE Universal M/P Heatcool. Defrost controller for high and low temperature. For use in upright cabinets, cold stores, control panels & heated cabinets
Controller – LAE AT2-5 BS4E-AG – 00-556187 T1 -Air Probe – SN4K15P1 – 00-556187 T2 -Evaporator Probe – SN4K15P2 – 00-556188 Indicators and Buttons – AT1-5 Indicators and Buttons – AT2-5 Symbol Reason Button Use Alarm Manual Defrost/Decrease Button Thermostat Output Increase/ Manual Activation Button Auxiliary Output
23/11/2018 · Learn how to configure the LAE LTR-5 thermostat, which features a single relay and probe. For a PTC probe, use the LTR-5T; for an NTC probe, use the LTR-5C. Unlike some other LAE controllers
ACI-5 INSTRUCTION FOR USE Thank you for having chosen a LAE e/ectronyc product. Before insta//ing the instrument, please read these instructions carefuffy to ensure maximum performance and safety DESCRIPTION aura Fig. 1 – Front pane/ Info / Enter button Modify Setpoint 1 / Decrease button INSTALLATION Insert the controller through a hole measuring 7 Ix29 mm; INDICATION OUTI Channel …
Indicators and Buttons – AT1-5 Indicators and Buttons – AT2-5 Display – for both Controllers During normal operation the display shows either the temperature measured or one of the following indicators: Information Menu – for both Controllers The information available in the menu is shown below: Symbol Reason Button Use Alarm Manual Defrost
LAE Electronic are a familiar and trusted name in electronic temperature control. We have been supplying high-quality thermometers, digital controllers and defrost controllers from LAE for nearly 20 years as their exclusive UK distributor.Our knowledge of LAE products is second-to-none, enabling us to provide our customers with detailed advice and technical support.
26/11/2018 · Learn how to configure an AT2-5 digital controller from LAE Electronic. This controller features three relays, which are often set to run fans, a compressor and a defrost control schedule. This
View and Download LAE electronic LTR-5 instructions for use online. LTR-5 Temperature Controller pdf manual download.
31/03/2016 · 1967 Shelby GT500 Barn Find and Appraisal That Buyer Uses To Pay Widow – Price Revealed – Duration: 22:15. Jerry Heasley Recommended for you
INSTRUCTIONS FOR INSTALLATION AND USE. AT2-5
https://www.youtube.com/embed/G8ZxREd1gow
AT1-5 INSTRUCTIONS FOR USE Lae Electronic
Lae At1-5 Controller Manual WordPress.com
LAE ELETRONIC AT2-5 (01) PDF MANUAL
26/11/2018 · The AT2-5 controller from LAE Electronic features a second set switching mode. This is often used in chillers to manually switch to an extra group of freezer settings when a button is pressed.
Image Description Information Temperature or Humidity Controller. Runs on mains power supply. Single output On/Off or PID Thermostat or Humidistat. Panel Cutout 71 x 29mm. Fact Sheet
View and Download Master Bilt LAE Controller BMG/TMG 48 installation & operation manual online. LAE CONTROLLER. LAE Controller BMG/TMG 48 Refrigerator pdf manual download. Also for: Lae controller bmg/tmg 52, Lae controller bmg/tmg 74, Lae controller bmg/tmg 80, Lae controller bmg/tmg…
Lae At1-5 Controller Manual ZOT-AC1 key Connection to LAE TAB supervisory systems On request, the AT1-5 is also available with gasket for a better protection between bezel and metal panel.
New LAE controller for Plug-in cabinets Dear Sirs, with the aim of a continuous improvement we are going to introduce our new LAE electronic controller in our plug-in cabinets: CRONOS IT2000X GLYCOS PROTEUS PLUS The reason that drive us to make this change is the better performance of LAE controller compared with EC 10
Manual Information & Health & Safety Notes 1 Environmental Management Policy 2 Disposal Requirements 2 Controller Warning & Cabinet Description 3 LD1 & LD2 Controller & Operation 3 to 4 Alarm & Warnings 4 to 5 Parameter setting & Adjustment 5 Parameters 6 to 7 AT1-5 & AT2-5 Controller Operation 8 to 9 Alarms & Warnigns 9 to 10
Service manual MCDU 11/1 and MCDU 11/2 LAE microprocessor digital temperature controllers November 2000 Page 5 2. Turn off the unit, press key [1] and [2] and, by keeping them pressed, turn on the unit. If this operation has been correctly made, ‘tHS” will appear on display. Access to all parameters and to their own pre-programmed values is
Xtra Cabinets FXT602H & L FXT1352H & L with Controllers
LAE Control Equipment / LAE AT2-5 Three Relay Temperature & Defrost Controllers / AT2-5BS4U-AG; AT2-5BS4U-AG SKU: AT2-5BS4U-AG. Availability: In stock. .51 . Qty: • A universal refrigeration controller • Replaces the function of a thermostat, a defrost clock, a defrost klixon, a fan delay switch, and temperature gauge. • A moderate capacity relay for compressor control (5 amp
We stock a full range of defrost controllers for process control application including refrigeration and cold rooms. LAE Split Defrost Controller BIT25B1S3E-A: Defrost Controller BIT25B1S3E-A Only Defrost Controller BIT25B1S3E-A With LCD-5S Display And Cable (+ £20.00) Add to Cart. read more… LAE Defrost Controller AH1-5. LAE Defrost Controller AH1-5. Price £122.00. Add to Cart. read
LTR-5CSRE-A Controller Service Manu al ISO 14001 Issued July 2010 ISO 9001. 1 Contents Manual Information & Health & Safety Notes 1 Environmental Management Policy 2 Disposal Requirements 2 EPROG600X Description 3 Controller Operation 3 to 4 Configuration of Parameters 4 Technical Data 4 Cabinet Controller Default 5 Wiring Diagram 6 Troubleshooting & Notes 7 Service Manual Information …
LAE Electronic are a familiar and trusted name in electronic temperature control. We have been supplying high-quality thermometers, digital controllers and defrost controllers from LAE for nearly 20 years as their exclusive UK distributor.
Shop. Connexion|Créer un compte. Login
Filsa BC52 – manual Filsa LIT-1 – manual . LAE. LAE AC1-5 LAE AC1-2W LAE AC1-27 LAE LTR-5 LAE AD2-5 LAE AD3-5 LAE AH1-5 LAE AT1-5 LAE AT2-5 LAE LTR LT6 LAE LTR LT12 LAE LTR15 LAE LTS LAE LTW12 LAE LTW15 LAE MTC11 LAE MTR MTC MHR MHC4 LAE MTW11 LAE MTW12. Pola. Pola HP11 – Manual Pola HP12 – Manual Pola HP13 – Manual Pola HP14 – Manual Pola HP15
New LAE controller for Plug-in cabinets holodko.ru
High or Low Temperature upright cabinets and counters, cold stores, plug-in display cases, control panels, heated cabinets.
E-mail: sales@lae-electronic.com AT2-5 INSTRUCTIONS FOR USE MODE D’EMPLOI AT2-5 MODE D’EMPLOI Nous vous remercions d’avoir choisi un produit LAE electronic. Pour que votre instrument soit le plus sûr et le plus performant possible, il est indispensable d’en lire attentivement le mode d’emploi. DESCRIPTION INDICATIONS Tout en maintenant la touche Sortie thermostatation Sortie
26/11/2018 · Got a further question about programming an LAE controller? We can help. Contact our technical support team on +44 (0)1483 869 069 or email technical@hawco.co.uk. We can help.
indications depend on the operating status of the controller. TABLE 1 gives the indications associated with the various states. 2.1 STANDBY. If button is pressed for 3 seconds, it allows the AT1-5 to be put on a standby, or to resume output control (with parameter SB=YES only). An indication on the display shows that the outputs are off
We thank you for choosing an LAE controller. Before proceeding to the installation of the CDC 12, please read this instructions sheet carefully; only in this way you will obtain maximum performances and safety. 1. INSTALLATION 1.1 The CDC122T1R2 and CDC122T1R3B have got a size of 77x35x77 mm (WxHxD), while the CDC122T1R3G and CDC122T1R3J have got a size of 77x35x97 mm (WxHxD). The …
AT2-5 INSTRUCTIONS FOR USE Thank you for having chosen a LAE electronic product. Before installing the instrument, please read these instructions carefully to ensure maximum performance and safety. DESCRIPTION INDICATIONS Thermostat output is released, the newly programmed value is stored and the following parameter is displayed. Fan output
RESETTING THE LAE CONTROL TO FACTORY DEFAULT Figure 1 Detail image of LAE Control Display. Note: The case must be powered on to reset the controller settings. 1. Locate the LAE Controller Display on your specific case. It is typically located near the compressor. 2. Hold down both the “i” and the “x” buttons for 5 seconds. The parameter
Procedure for Changing /removing the alarm CL on the LAE AT1-5 Controller The front panel of the LAE RL2 Controller has an LED display and four push-buttons which will be referred to in numerical order 1-4 from left to right. The LED Display normally shows the measured temperature.
AT1-5 INSTRUCTIONS FOR USE Thank you for having chosen a LAE electronic product. Before installing the instrument, please read these instructions carefully to ensure maximum performance and safety. DESCRIPTION Fig.1 — Front panel [6] Info / Setpoint button. [7] Increase / Manual mode button. [8] Manual defrost / Decrease button. [9] Exit
LAE CONTROLLER, AT2-5BQ4U-2JW. Order from Heritage Parts the leading online provider of OEM commercial kitchen replacement parts. Most parts ship same day.
https://www.youtube.com/embed/UGW2K6KnKtE
Lae Controllers Ltr 5 Series – Thermal Products
5/16 Rev. B 57-02405 Installation & Operations Manual LAE – AT2-5 Controller Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988
Service manual FDC 121 and FDC 122 microprocessor control panels November 2000 Page iii Safety of personnel Liability Foster Refrigerator (UK) Limited decline responsibility when …
LTR-5 INSTRUCTIONS FOR USE Thank you for having chosen a LAE electronic product. Before installing the instrument, please read these instructions carefully to ensure maximum performance and safety. DESCRIPTION INDICATIONS au-ra Thermostat output etae Increase button. Exit/ Stand-by button. Fig.l— Setpoint button. Decrease button. INSTALLATION Front panel Insert the controller through a hole
5.1 Temperature control is based upon the comparison between temperature T1, the setpoint SP and the hysteresis HYS. The thermostat operation is determined by the value programmed to HYS: if greater than 0 there will be COOLING control, if lower than 0 there will be HEATING control, if HYS=0 then the thermostat will be excluded permanently.
Freestanding upright cabinets and counters, cold stores, plug-in display cases, control panels, heated cabinets.
1.1 The AT2-5, size 77x35x77 mm differently, with DFR=0, timed defrost only is removed, while manual defrost remains active. 5.2 Once defrost has started, the compressor and defrost outputs are controlled according to parameter DTY and OAU. As a matter of fact, please note that the AUX output is configured for defrost control only with OAU=DEF. Table 3 5.3 Defrost lasts for the time DTO
1 BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652indian shrubs names pictures pdf23/11/2018 · Learn how to configure an AC1-5 digital controller from LAE Electronic for use with two relays, one for a compressor and the other for a heater. This makes the AC1-5 a versatile choice for hot
Two channel universal Controller, ON/OFF or PID AC1-2W . Two channel universal Controller, ON/OFF or PID AC1-5 . Two channel universal Controller, ON/OFF or PID LTC15 : LTR-5 . Single output ON/OFF or PID controller LTR15 : LTW15 : MHC12 : MHC27 : MHC4 : MHR4 : MTC12 : MTC27 : MTR12 : MTR4 : MTR6 : MTW11 : MTW12 : HEADQUARTERS. Via Padova, 25 31046 Oderzo (Tv) Italy. PHONE NUMBERS. …
Button , when pressed for 3 seconds, allows the controller to be put on a standby or output control to be resumed (with SB=YES only). KEYPAD LOCK The keypad lock avoids undesired, potentially dangerous operations, which might be attempted when the controller is operating in
our know-how for state-of-the-art products . applications . professional refrigeration
BMG/TMG27 48 52 74 80 LAE CONTROLLER Installation

LAE ELECTRONIC LTR-5 INSTRUCTIONS FOR USE Pdf Download.
LAE Controller Setting Alarm Values - YouTube
Programming an LAE LTR-5 Digital Controller YouTube
https://www.youtube.com/embed/9cwQFyNGRd0

Pro-therm Controls Download manuals
Document3 Pro-therm
LAE Universal M/P Heatcool Control Defrost controller

Procedure for Changing /removing the alarm CL on the LAE
dometic penguin ii installation manual

HK LAE Controller Programming YouTube

Programming an LAE AT2-5 Digital Controller YouTube

Lae Electronic

https://en.wikipedia.org/wiki/Airline_codes
Controllers Products Lae Electronic
Defrost Controllers Saturn Sales
ISTR AT2-5 FRANCESE Lae Electronic
TRUE TEMPERATURE CONTROLS OPERATION WWW TRUEMFG
TRUE MANUFACTURING COMPANY TGU-2 INSTALLATION
https://www.youtube.com/embed/L5IUVAOV1f8

LAE ELECTRONIC AT2-5 CONTROL 115V SPEED CONTROL

6 thoughts on “Lae at2 5 controller manual

  1. 1 BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652

    HK LAE Controller Programming YouTube
    AT2-5 Lae Electronic
    AT1-5 Lae Electronic

  2. Lae At1-5 Controller Manual ZOT-AC1 key Connection to LAE TAB supervisory systems On request, the AT1-5 is also available with gasket for a better protection between bezel and metal panel.

    F Series Cabinets & Counters AT1-5 & AT2-5 Controllers
    Service manual MCDU 11/1 and MCDU 11/2 LAE microprocessor
    ISTR AT2-5 FRANCESE Lae Electronic

  3. Manual Information & Health & Safety Notes 1 Environmental Management Policy 2 Disposal Requirements 2 Controller Warning & Cabinet Description 3 LD1 & LD2 Controller & Operation 3 to 4 Alarm & Warnings 4 to 5 Parameter setting & Adjustment 5 Parameters 6 to 7 AT1-5 & AT2-5 Controller Operation 8 to 9 Alarms & Warnigns 9 to 10

    Service manual FDC 121 and FDC 122 microprocessor control
    Fixing An E1 Probe Fault LAE AT2 5 Digital Controller
    LAE ELETRONIC AT2-5 (01) PDF MANUAL Manual-Hub.com

  4. 5/16 Rev. B 57-02405 Installation & Operations Manual LAE – AT2-5 Controller Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988

    LAE Electronics Digital Controllers Hawco Buy Online
    INSTRUCTIONS FOR INSTALLATION AND USE. AT2-5
    LAE ELECTRONIC LTR-5 INSTRUCTIONS FOR USE Pdf Download.

  5. ACI-5 INSTRUCTION FOR USE Thank you for having chosen a LAE e/ectronyc product. Before insta//ing the instrument, please read these instructions carefuffy to ensure maximum performance and safety DESCRIPTION aura Fig. 1 – Front pane/ Info / Enter button Modify Setpoint 1 / Decrease button INSTALLATION Insert the controller through a hole measuring 7 Ix29 mm; INDICATION OUTI Channel …

    MASTER BILT LAE CONTROLLER BMG/TMG 48 INSTALLATION
    Procedure for Changing /removing the alarm CL on the LAE
    Programming an LAE AT2-5 Digital Controller YouTube

  6. 26/11/2018 · Got a further question about programming an LAE controller? We can help. Contact our technical support team on +44 (0)1483 869 069 or email technical@hawco.co.uk. We can help.

    LAE Controller Setting Alarm Values – YouTube
    LAE Universal M/P Heatcool Control Defrost controller
    ISTR AT2-5 FRANCESE Lae Electronic

Comments are closed.